ASTM F2413-05 PDF

1 | Page. ASTM. American Society For Testing and Materials. F Standard Specification for Performance Requirements for Foot. Protection. Abstract. Learn about ASTM footwear standards and how to properly read a label. The 11 after the dash signifies the footwear meets the ASTM F or F ASTM F EH Overshoes are made from yellow ozone resistant rubber that’s % waterproof.

Author: Juzragore Mezirr
Country: Nepal
Language: English (Spanish)
Genre: Video
Published (Last): 17 July 2010
Pages: 407
PDF File Size: 2.71 Mb
ePub File Size: 14.5 Mb
ISBN: 429-7-86547-501-9
Downloads: 55728
Price: Free* [*Free Regsitration Required]
Uploader: Vill

The device must show no sign of corrosion after being exposed to a five percent salt solution for 24 hours. One shoe of each pair must be clearly and legibly wstm e.

This specification covers the minimum design, performance, testing, and classification requirements, and prescribes fit, function, and performance criteria for footwear designed to be worn to provide protection f2413-5 a variety of workplace astk that can potentially result in injury. It must be capable of withstanding the application of 18, volts at 60 hertz for one minute with no current flow or leakage current in excess of one milliampere under dry conditions.

All footwear manufactured to the ASTM specification must be marked with the specific portion of the standard with which it complies. It is not the intention of this specification to serve as a detailed manufacturing or purchasing specification, but can be referenced in purchase contracts to ensure that minimum performance requirements are met.

ASTM F EH Footwear Overshoes

Link to Active This link will always route to the current Active version of the standard. This specification covers the minimum design, performance, testing, and classification requirements, and prescribes fit, function, and performance criteria for footwear designed to protect against a variety of workplace hazards.

The electrical resistance must range between zero andohms. The puncture-resistant footwear must show no signs of cracking after being subjected to 1. Standard specification for performance requirements for asrm safety toecap footwear. The purpose of this standard is to summarize the requirements for certifying protective footwear by independent, third party laboratories. Electrical hazard EH footwear is manufactured with non-conductive, electrical shock-resistant soles and heels.

  KRAUSER PUA PDF

Instead, this specification can be referenced in purchase contracts to ensure that minimum performance ff2413-05 are met. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

This plate is an integral and permanent part of the footwear. Footwear conforming to this specification must meet the performance requirements for the following: The metatarsal designation Mt and rating i.

Work Item s – proposed revisions of this standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. I’m a client Email. Any changes to the original components of safety toe footwear, such as replacing or adding foot beds or inserts, could cause failure to any or all parts of the ASTM standard invalidates the safety marking.

These are used to designate conductive Cd properties, electrical hazard resistance properties EHfootwear designed to reduce the accumulation of excess static qstm SDand puncture resistance PR. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. The outsole is intended to provide a secondary source of electric shock-resistance protection for the wearer against the hazards associated with incidental contact with live electrical circuits, electrically-energized conductors, parts, or apparatuses.

Registering your company allows you to see your price matrix for our product line, place orders, view your order history, and adjust your account details and settings in real time. It indicates that the protective footwear meets the performance requirements of ASTM F, issued in Impact Resistant Footwear and Section 5.

ASTM F2413-05 EH Footwear Overshoes

Safety and client access have no downtime. The footwear must have a lower limit of electrical resistance of ohms and an upper limit of ohms. Conductive Cd footwear is intended to provide protection for the wearer against hazards resulting from static electricity build-up and to reduce the possibility of igniting explosives and volatile chemicals.

  BACK IN THE USSA KIM NEWMAN PDF

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. After your consent, this site will use cookies for statistical and advertising purposes, as well as to facilitate information sharing on social networks.

Footwear conforming to this specification shall meet the performance requirements for the following: It also identifies the existence of impact resistance Ithe impact resistance rating 75, 50 or 30 foot-poundscompression resistance Cand the compression resistance rating 75, 50, or 30, which correlate to pounds, pounds, and pounds of compression respectively.

Line four is used only when more than three sections of the standard apply to the footwear.

ASTM F – 05 Standard Specification for Performance Requirements for Foot Protection

The footwear must facilitate electrical conductivity and the transfer of static electricity build-up from the wearer to the ground. It is not the intention of this specification to serve as a detailed sstm or purchasing specification. Accept all cookies or Manage cookie settings. Historical Version s – view previous versions of standard. Puncture-resistant PR footwear features a puncture-resistant plate positioned between the insole and outsole.

Static dissipative SD footwear is designed to provide protection against hazards associated with exceedingly low footwear resistance and to maintain a sufficiently high level of resistance to reduce the possibility of electric shock.

Following these assessments, the requirements of additional sections—such as metatarsal protection, conductive protection, electric hazard resistance, static dissipative protection, and protection against punctures—can f241305 met.